IEC 60099-8:2017 RLV (Redline version)

Title

Language: EN Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Abstract

Language: EN IEC 60099-8:2017 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way to compare all the changes between this standard and its previous edition. The Redline version is not an official IEC Standard, only the current version of the standard is to be considered the official document. IEC 60099-8:2017 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers.  This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document: - switching impulse spark-over voltage; - residual voltage at steep current and switching current impulse; - thermal stability; - long-duration current impulse withstand duty; - power-frequency voltage versus time characteristics of an arrester; - disconnector test; - aging duties by power-frequency voltage. Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this document. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The Lightning discharge capability test has been completely re-written and re-named to Test to verify the repetitive charge transfer rating, Qrs with lightning discharges to reflect changes introduced in IEC 60099-4 Ed.3 (2014) regarding new methods for rating the energy and charge handling capability of metal-oxide arresters. In addition to testing to evaluate the performance of the MO resistors, procedures for evaluating the performance of the EGLA series gaps have been introduced. - Omissions from Ed. 1 of this standard have been included, notably an RIV test and a means for determining the thermal time constant of the SUV portion of the EGLA. - Definitions for new terms have been added - A number of NOTES in Ed. 1 have been converted to normative requirements Keywords: externally gapped line arresters (EGLA), lightning-caused over-voltages

Language(s)
Language: EN
Edition
2.0
Date of issue
14.11.2017
TC 37
ICS Codes
29.240.10
Publication number
60099
Preview

To use the preview feature, please enable JavaScript in your Browser


Price (excl. VAT)
€ 354,50 (Download and hardcopy)
Delivery format
postal download (137 Pages)

Warenkorb

Back

Legend

Document for download (PDF) PDF document (download version)
ZIP File for download ZIP file (download version)
Shipping item Paper (print version)/shipping item
Adobe DRM ePub File E-book (Adobe DRM ePub)
Storage medium Storage medium
Database Database
Bezugsart Online Viewing access (7-days available online)
Mandatory Standard according current regulation Mandatory Standard according current regulation

This website uses cookies. By continuing to use this website you are giving consent to cookies being used. For information on cookies, please look at our privacy statement.