IEC TS 61201:2007

Title

Language: EN Use of conventional touch voltage limits - Application guide

Language: FR Utilisation des tensions limites conventionnelles de contact - Guide d'application

Abstract

Language: EN Provides guidance on the use of conventional touch voltage limits with reference to thresholds given in IEC 60479-5. Consideration is given to different physiological effects, environmental conditions, contact conditions, etc. This specification only discusses voltages for sinusoidal a.c. at 50/60 Hz and pure d.c. having no significant a.c. component. This specification does not consider immersion of body parts or medical applications. Touch voltage limits are for use by technical committees as guidance for the determination of their own specific limits. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. It is not intended for use by manufacturers or certification bodies One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications. This second edition cancels and replaces the first edition which was issued as a technical report in 1992. It constitutes a technical revision and now has the status of a technical specification. The main changes with respect to the previous edition are listed below: - proposal of maximum contact areas for various conventional touch voltage limit; - introduction of different current pathways through the human body for the selection of conventional touch voltage limit; - introduction of conventional touch voltage limit corresponding to the startle reaction current threshold, the inability of let-go current threshold and the ventricular fibrillation current threshold; - possibility of interpolation on contact area for other conventional touch voltage limits. It has the status of a basic safety publication in accordance with IEC Guide 104 and ISO/IEC Guide 51.

Language(s)
Language: EN Language: FR
Edition
2.0
Date of issue
30.08.2007
TC 64
ICS Codes
13.260, 29.020, 91.140.50
Publication number
61201
Preview

To use the preview feature, please enable JavaScript in your Browser


Price (excl. VAT)
€ 90,90 (Download and hardcopy)
Delivery format
postal download (33 Pages)

Warenkorb

Back

Legend

Document for download (PDF) PDF document (download version)
ZIP File for download ZIP file (download version)
Shipping item Paper (print version)/shipping item
Adobe DRM ePub File E-book (Adobe DRM ePub)
Storage medium Storage medium
Database Database
Bezugsart Online Viewing access (7-days available online)
Mandatory Standard according current regulation Mandatory Standard according current regulation

This website uses cookies. By continuing to use this website you are giving consent to cookies being used. For information on cookies, please look at our privacy statement.