IEC 61936-1:2010

Title

Language: EN Power installations exceeding 1 kV a.c. - Part 1: Common rules

Language: FR Installations électriques en courant alternatif de puissance supérieure à 1 kV - Partie 1: Règles communes

Abstract

Language: EN IEC 61936-1:2010 provides common rules for the design and the erection of electrical power installations in systems with nominal voltages above 1 kV a.c. and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended. For the purpose of interpreting this standard, an electrical power installation is considered to be one of the following: a) Substation, including substation for railway power supply; b) Electrical installations on mast, pole and tower; Switchgear and/or transformers located outside a closed electrical operating area; c) One (or more) power station(s) located on a single site. The installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded; d) The electrical system of a factory, industrial plant or other industrial, agricultural, commercial or public premises. The electrical power installation includes, among others, the following equipment: rotating electrical machines; switchgear; transformers and reactors; converters; cables; wiring systems; batteries; capacitors; earthing systems; buildings and fences which are part of a closed electrical operating area; associated protection, control and auxiliary systems; large air core reactor. NOTE: In general, a standard for an item of equipment takes precedence over this standard. This standard does not apply to the design and erection of any of the following: - overhead and underground lines between separate installations; - electric railways; - mining equipment and installations; - fluorescent lamp installations; - installations on ships and off-shore installations; - electrostatic equipment (e.g. electrostatic precipitators, spray-painting units); - test sites; - medical equipment, e.g. medical X-ray equipment. This standard does not apply to the design of factory-built, type-tested switchgear for which separate IEC standards exist. This standard does not apply to the requirements for carrying out live working on electrical installations. This second edition cancels and replaces the first edition, published in 2002. It constitutes a technical revision. The main changes with respect to the previous edition are listed below: - new table of references for additional agreements between manufacturer/contractor/planer and user/orderer/owner (4.1.2); - addition of minimum clearances in air not standardized by IEC but based on current practice in some countries (Annex A); - deletion of nominal voltages (Table 1, Table 2, Clause 5); - addition of regulations for fuses (6.2.15); - simplification of regulations for escape routes (7.5.4); - deletion of special regulations for operating aisles (7.5.4); - modification of clearances for fire protection (Table 3); - modification of safety criteria for earthing systems (10.2.1); - modified curves of permissibly touch voltages (Figure 12, Annex B); - deletion of numbering of subclauses without headlines; - change of "should" to "shall" in many cases or change of subclauses with "should" to a note. The contents of the corrigendum of March 2011 have been included in this copy.

Language(s)
Language: EN Language: FR
Edition
2.0
Date of issue
31.08.2010
TC 99
ICS Codes
29.020, 29.080.01
Publication number
61936
Preview

To use the preview feature, please enable JavaScript in your Browser


Price (excl. VAT)
€ 290,90 (Download and hardcopy)
Delivery format
postal download (210 Pages)

Warenkorb

Back

Legend

Document for download (PDF) PDF document (download version)
ZIP File for download ZIP file (download version)
Shipping item Paper (print version)/shipping item
Adobe DRM ePub File E-book (Adobe DRM ePub)
Storage medium Storage medium
Database Database
Bezugsart Online Viewing access (7-days available online)
Mandatory Standard according current regulation Mandatory Standard according current regulation

This website uses cookies. By continuing to use this website you are giving consent to cookies being used. For information on cookies, please look at our privacy statement.