IEC 60079-13:2017

Title

Language: EN Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"

Language: FR Atmosphères explosives - Partie 13: Protection du matériel par salle à surpression interne "p" et salle à ventilation artificielle "v"

Abstract

Language: EN IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment: – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurization; – located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation; – located in a non-hazardous area, containing an internal source of gas/vapour release and protected by artificial ventilation; – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere containing an internal source of gas/vapour release and protected by both pressurization and artificial ventilation. The term "room" used in this document includes single rooms, multiple rooms, a complete building or a room contained within a building. A room is intended to facilitate the entry of personnel and includes inlet and outlet ducts. An acoustic hood and other like enclosures designed to permit the entry of personnel can be considered as a room. This document also includes requirements related safety devices and controls necessary to ensure that artificial ventilation, purging and pressurization is established and maintained. A room assembled or constructed on site, can be either on land or off-shore. The room is primarily intended for installation by an end-user but could be constructed and assessed at a manufacturer’s facility, where the final construction such as ducting can be completed on site. This document does not specify the methods that may be required to ensure adequate air quality for personnel with regard to toxicity and temperature within the room. National or other regulations and requirements may  exist to ensure the safety of personnel in this regard. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p"; b) addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv"; c) definition of the differences between pressurization and artificial ventilation types of protection; d) removal of protection of rooms with an inert gas or a flammable gas from the scope of this document; e) addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines.

Language(s)
Language: EN
Edition
2.0
Date of issue
22.05.2017
TC 31
ICS Codes
29.260.20
Publication number
60079
Preview

To use the preview feature, please enable JavaScript in your Browser


Price (excl. VAT)
€ 181,80 (Download and hardcopy)
Delivery format
postal download (35 Pages)

Warenkorb

Back

Legend

Document for download (PDF) PDF document (download version)
ZIP File for download ZIP file (download version)
Shipping item Paper (print version)/shipping item
Adobe DRM ePub File E-book (Adobe DRM ePub)
Storage medium Storage medium
Database Database
Bezugsart Online Viewing access (7-days available online)
Mandatory Standard according current regulation Mandatory Standard according current regulation

This website uses cookies. By continuing to use this website you are giving consent to cookies being used. For information on cookies, please look at our privacy statement.